% Plot results of 2000 May 3 calibration at Palmer Station. See the data file for data, comments. a=load('PalmerCal2000.txt'); [f,i]=sort(a(:,1)); f=a(i,1); % Frequency, Hz V2cal=a(i,5); % Voltage pp at preamp LR_NS=a(i,6); % Signal back at line receiver, North South LR_EW=a(i,7); % Signal back at line receiver, East-West BB_NS=a(i,8); % Signal from I2000 box, broadband monitor, North South BB_EW=a(i,10); % Signal from I2000 box, broadband monitor, East-West NB_NS=a(i,9); % Signal from I2000 box, narrowband monitor, North South NB_EW=a(i,11); % Signal from I2000 box, narrowband monitor, East-West figure; loglog(f,LR_NS,'r.-',f,LR_EW,'r.:',f,BB_NS,'g.-',f,BB_EW,'g.:', f,NB_NS,'m.-',f,NB_EW,'m.:'); xlabel('Frequency (Hz)'); ylabel('Voltage, RMS (mV)'); title('Calibration of Palmer VLF receiver'); xlim([min(f) max(f)]); legend('Line receiver, NS','Line receiver, EW','Broadband, NS','Broadband, EW','Narrowband, NS','Narrowband, EW');